Ene 01Energy and carbon performance for regulated energy usesUp to 9 credits + 3 innovation credits
Regulated heating, cooling and building-services energy and carbon assessment; model and design-option support.
✓
Ene 02Prediction of Operational Energy and CarbonUp to 5 credits + 4 innovation credits
Predictive operational-energy modelling, scenario analysis, assumptions register and traceable result sets.
✓
Ene 07Flexible demand response1 credit + 1 exemplary credit
HVAC, DHW, EV charging, storage and control-strategy review for flexible demand capability.
✓
Ene 08Installed controlsUp to 2 credits + 1 exemplary credit
Heating, cooling and building-services control functionality review against the selected system configuration.
✓
Hea 04Indoor air qualityUp to 3 credits + 2 exemplary credits
Ventilation and IAQ design calculations, strategy and documentation support; post-construction air testing remains a separate field activity.
✓
Hea 05Thermal Comfort1 credit
Full dynamic thermal analysis, overheating assessment, PMV / PPD and future-climate scenarios.
✓
Pol 01Impact of refrigerantsUp to 3 credits
Refrigerant inventory, GWP / impact calculations and leak-detection design review based on project and manufacturer data.
✓
Pol 02Local air qualityUp to 3 credits
Heating and hot-water combustion strategy, local-emissions / NOx review and non-combustion design assessment.
✓
Wat 01Water consumptionUp to 5 credits + 1 innovation credit
Sanitary fitting flow / flush data, occupancy inputs and building water-consumption calculations.
✓
Wat 03Water leak detection and preventionUp to 2 credits (non-residential)
Leak-detection strategy and controls review, including coordination with hydrant and sprinkler water systems where applicable.
✓
Man 04Commissioning and handoverUp to 4 credits
Design-stage commissioning review, commissioning documentation and technical handover support; verification can require targeted attendance.
✓
Hea 06Acoustic performanceUp to 4 credits
Mechanical plant and building-services acoustic calculation / design support; suitably qualified acoustician requirements may apply.
✓
SITE QAAirtightness & thermography1 credit within Man 04 · Envelope testing
Building-envelope airtightness testing and thermographic diagnostics to support fabric-performance verification and model-input QA where applicable to the selected BREEAM route.
|
✓
EAp1Operational Carbon Projection and Decarbonization PlanRequired prerequisite
Operational-carbon projection, HVAC / energy scenario comparison and decarbonization pathway support.
✓
EAp2Minimum Energy EfficiencyRequired prerequisite
Whole-building energy modelling and baseline / proposed performance assessment for the applicable pathway.
✓
EAc1ElectrificationUp to 5 points
Heat-pump and electric building-services scenarios, fossil-fuel displacement and supporting energy calculations.
✓
EAc2Reduce Peak Thermal LoadsOption 4 · Path 3 — Energy SimulationUp to 5 points
Coincident peak heating and cooling load simulation, including ventilation, with design-scenario comparison.
✓
EAc3Enhanced Energy EfficiencyEnergy Simulation pathwayUp to 10 points
Whole-building energy simulation aligned with the applicable ASHRAE 90.1 Appendix G methodology.
✓
EAc6Grid InteractiveUp to 2 points
Demand flexibility, controls, load shifting and grid-interactive building-services strategy support.
✓
EQp2Fundamental Air QualityRequired prerequisite
ASHRAE 62.1 ventilation and filtration design review, outdoor-air calculations and IAQ documentation support.
✓
EQc1Enhanced Air Quality1 point
Increased-ventilation or enhanced IAQ design assessment and supporting calculations.
✓
EQc2Occupant ExperienceOption 3 — Thermal Environment1 point
ASHRAE 55 thermal-comfort assessment, including operative temperature and PMV / PPD analysis where applicable.
✓
EQc2Occupant ExperienceOption 4 — Sound EnvironmentUp to 2 points
Acoustic criteria, mechanical-noise calculations and design support; project pathway may also use measurements.
✓
EAp5Fundamental Refrigerant ManagementRequired prerequisite
Refrigerant inventory, GWP and alternative-refrigerant design review; installation leak checks remain a field activity.
✓
EAc7Enhanced Refrigerant ManagementUp to 2 points
Low-GWP refrigerant assessment, weighted GWP calculations and refrigerant leakage-management design support.
✓
WEp1Water Metering and ReportingRequired prerequisite
Metering architecture, water-use boundaries and documentation support from design information.
✓
WEp2Minimum Water EfficiencyRequired prerequisite
Indoor water-use calculations from fixture flow / flush rates and occupancy assumptions.
✓
WEc1Water Metering and Leak Detection1 point
Submetering and leak-detection strategy, controls concept and documentation support.
✓
WEc2Enhanced Water EfficiencyUp to 8 points
Enhanced indoor water-use reduction calculations and design-option comparison.
✓
EAp3Fundamental CommissioningRequired prerequisite
MEP commissioning-plan, design-review and documentation support; independent CxP and field verification requirements apply.
✓
EAc5Enhanced CommissioningEnvelope · Airtightness & thermographyUp to 4 points
Enhanced MEP commissioning support plus enclosure-pathway airtightness testing, field verification and infrared thermography where selected.
|
✓
T01Thermal PerformancePrecondition · no points
Thermal-comfort design support using ASHRAE 55 metrics, operative temperature, PMV / PPD and adaptive comfort analysis.
✓
T04Individual Thermal ControlUp to 3 points
Personal thermal-control and comfort-design support, including modelling of thermal conditions where useful.
✓
T07Humidity Control1 point
Humidity-control design and dynamic humidity analysis where the selected WELL pathway accepts modelling evidence.
✓
T09Outdoor Thermal ComfortUp to 3 points
Outdoor thermal-comfort and microclimate modelling support where required by the selected project strategy.
✓
SUPPORTAirtightness & thermographySupporting service · no WELL points
Envelope diagnostics supporting thermal-comfort, condensation and IAQ investigations. This is a supporting service rather than a standalone WELL feature.
|
✓
EEM01–EEM12Envelope, passive design & comfortEfficiency measure · no credit points
EDGE App modelling for glazing ratio, reflectance, shading, insulation, glazing performance, airtightness, natural ventilation and related passive-design measures.
✓
EEM13–EEM21HVAC, heating, DHW & ventilationEfficiency measure · no credit points
Cooling and heating efficiency, variable-speed drives, fresh-air pre-conditioning, room controls, domestic hot water, economizers and demand-controlled ventilation.
✓
EEM22–EEM26Lighting & demand controlsEfficiency measure · no credit points
Internal and external lighting efficiency, lighting controls, skylight-related inputs and CO-based parking ventilation strategies.
✓
EEM27–EEM29Cold storage & equipment efficiencyEfficiency measure · no credit points
Cold-storage envelope, refrigeration-efficiency and applicable appliance-efficiency inputs for relevant project typologies.
✓
EEM30–EEM32Metering & electrical efficiencyEfficiency measure · no credit points
Heating and cooling submetering, smart energy meters and power-factor-correction strategy documentation.
✓
EEM33–EEM37Renewables, additional savings & refrigerantsEfficiency measure · no credit points
On-site and off-site renewable energy, additional energy-saving measures, carbon-offset inputs and low-impact refrigerant assessment.
✓
WEM01/02/04/06–11Water-efficient fixtures & appliancesEfficiency measure · no credit points
Design-stage water-use inputs and documentation for showers, faucets, WCs, bidets, urinals, kitchen fittings and applicable appliances.
✓
WEM12–WEM17Water systems, reuse & meteringEfficiency measure · no credit points
Pool covers, efficient irrigation, rainwater harvesting, wastewater recycling, condensate recovery and smart water metering.
✓
EEM / QAAirtightness & thermographySupporting QA · no EDGE points
Airtightness-measure input verification and optional thermographic envelope QA; final evidence requirements remain subject to the EDGE audit pathway.
|
✓
7.1Construction of new buildingsTechnical screening criterion · no credit points
Primary-energy-demand / NZEB assessment and calculation support for the applicable taxonomy technical screening criteria.
✓
7.2Renovation of existing buildingsTechnical screening criterion · no credit points
Energy-performance assessment, including the applicable major-renovation route or primary-energy-demand reduction pathway.
✓
DNSHClimate risk & vulnerability assessmentDNSH criterion · no credit points
Physical climate-risk screening, future-climate scenarios and adaptation-measure assessment for building-performance risks.
✓
7.7Acquisition & ownership of buildingsTechnical screening criterion · no credit points
Energy-performance and supporting technical assessment for the applicable building-ownership criteria.
✓
9.3Energy-performance servicesTechnical screening criterion · no credit points
Building energy simulation and related engineering analysis supporting professional energy-performance services.
✓
DNSHWater efficiency assessmentDNSH criterion · no credit points
Fixture and sanitary-water performance review against the applicable DNSH water-efficiency requirements.
✓
7.1 · >5,000 m²Airtightness & thermal-integrity verificationTechnical requirement · no credit points
Airtightness testing and thermographic / thermal-integrity assessment for large new buildings where required by the applicable taxonomy criteria.
|